Carbon Monoxide Detector Combustion Analyzer
Fixed Detector, Transmitter Gas Analyzer
Gas Leak Detector Portable Detector
Refrigerant Leak Detector Stand Alone Detector
Amprobe Ultrasonic Gas Leak Detector
Ampr-ULD-300
320.05
Amprobe Ultrasonic leak detector
ampr-tmuld-300
436.45
Bacharach 120 VAC external audible alarm
3015-3070
134.95
Bacharach 120 VAC external visual alarm
3015-3069
164.95
Bacharach 120 VAC surge protector
3015-4121
299.95
Bacharach 120VAC External Audio-Visual Alarm
3015-3076
339.95
Bacharach 220 VAC surge protector
3015-4122
300.73
Bacharach 4?20 mA surge protector
3015-4123
199.95
Bacharach AGM300 Multi-Zone Ammonia Monitor, 12
3015-4192
5742.40
Bacharach AGM300 Multi-Zone Ammonia Monitor, 16
3015-4193
6101.30
Bacharach AGM300 Multi-Zone Ammonia Monitor, 4
3015-4190
5238.00
Bacharach AGM300 Multi-Zone Ammonia Monitor, 8
3015-4191
5529.00
Bacharach AGMSZ Ammonia Gas Monitor Single Zone
3015-4280
2473.50
Bacharach HGMSZ Halogen Gas Monitor Single Zone
3015-4200
2473.50
Bacharach Leakator 10 Combust. Gas Leak Detector
19-7051
294.95
Page 1 of 5
3015-4200
Bacharach HGMSZ Halogen Gas Monitor Single Zone
The Bacharach HGMSZ (Halogen Gas Monitor Single Zone) is designed for continuous single-point monitoring of CFC, HFC, HCFC and Halon refrigerant gases. The HGMSZ displays the type of gas being monitored, along with displaying both the current gas level and the peak gas level detected on its front panel LCD. The instrument retains a log of previous readings that can be easily accessed for analysis.
An internal audible alarm and front panel indicators are provided to signal alarm and fault conditions, and relay contacts can be used to trigger external alarm devices in the event of a system fault, or if a leak (small), spill (medium), or evacuation (large) level of gas is detected. The system also includes a 4?20 mA current loop interface that can be connected to remote monitoring equipment.
Easily complies with ASHRAE 15 requirements with a low-cost investment
Eliminate false alarms with use of non-dispersive IR source and sample draw system
Capable of detecting 30 of the most commonly used refrigerants and halogen gases
Measure all gases up to 10,000 ppm with a sensitivity of 1 ppm
Monitors a single zone located up to 50 feet from unit
Logging feature enables 200 gas readings to be stored
Three gas alarm levels that can be individually set
Bolt-in, bolt-out internal components so the unit never leaves the wall
Two-year warranty
Refrigerant Library: R‑11, R‑12, R‑21, R‑22, R‑23, R‑113, R‑114, R‑123, R‑124, R‑134a, R‑227, R‑236FA, R‑401a, R‑402a, R‑402b, R‑404a, R‑407a, R‑407c, R‑408a, R‑409a, R‑410a, R‑500, R‑502, R‑503, R‑507, R‑508b, H‑1211, H‑1301, H‑2404, N‑1230
Measuring Range: All gases 0 to 10,000 ppm
Input: Dedicated single zone
Output Signals: 4 SPDT, 5 Amp, 240 VAC relays; digital display; and a 4?20 mA DC current loop output
Detector Type: Single pass, non-dispersive infrared
Sensitivity: All gases 1 ppm
Accuracy: All gases ?10 ppm from 0 to 100 ppm, ?10% of reading from 100 to 10,000 ppm
Front Panel Indicators: MONITOR ON ? Green light ON when the unit is operating normally, or flashing during warm-up. SYSTEM FAULT ? Yellow light ON when there is a system fault. ALARM ? Red light ON when the gas level is above an alarm setting.
Response Time: 9 to 30 seconds, depending on tube length and gas concentration
Max. Monitoring Distance: Up to 50 feet from measuring point to monitor
Operating Temperature: 32 to 122?F (0 to 50?C)
Humidity: 5 to 90% RH, non-condensing
Altitude Limit: 2000 Meters
Power: 100?240 VAC, 50/60 Hz, 15 Watts
Size/Weight: 14"H x 18"W x 4.7"D / 7 lbs
Certification: UL 61010A-1, CSA 22.2, CE Mark
Price: $2473.50
Items:
Subtotal: $
Delivery: $
Gas leak detector, digital multimeter, carbon monoxide detector, pressure gauge. Whatever the product, HVAC tool.com has you covered!
We carry Dwyer, Leatherman, Fieldpiece, Maglite flashlight, Pelican flashlights, Robinair, TPI, UEI, Amprobe, Yellow Jacket, and Mastercool.